2026-11-18: Gitea down three times, its backup gate ran for tool-image bumps¶
Kind: reference (incident report)
Severity: critical · Status: resolved · Resolved by: each gate run ended on its own, after a drained merge by the operator agent (#3368, #3382 and the #1575 merge run); investigated by the operator agent (#3379), prevention by the owner's decision #3453 (skip when nothing upgrades), carried out by #3454 · Duration: three firings of 11 min (16:07:03–16:18:03, 18:31:03–18:42:03, 23:01:33–23:12:33 UTC); Gitea down 16:02–16:13, 18:26–18:37 and 22:57–23:07 · Taskbase task: #3379
Summary¶
ProbeFailed fired three times on 2026-11-18 for https://gitea.prod.skatzi.com and /api/healthz, each time for about 10 minutes. Helm did not replace Gitea: the last Helm revision is 12, from 2026-11-15. Each window came from the gitea-preupgrade backup gate, which scaled Gitea to 0 for its dumps. Three Renovate PRs had changed a tool image in the gate Job's pod template: #1538 (bitnami/kubectl digest), #1553 (amazon/aws-cli 2.41.0) and #1575 (amazon/aws-cli 2.41.1). Every merge recreated the Job, and the gate took a full backup from Gitea 28.3.0 "to" 28.3.0, the version Gitea was already running. The windows were expected: they were drain-class merges, and the operator drained each one as Renovate ADR §11 says. They were also avoidable, because nothing was being upgraded. The proposed fix is the owner's decision #3453. Separately, every probe failed for one minute at 13:24–13:25 while the Cilium 1.20.4 upgrade restarted the Cilium agents and cilium-envoy.
Impact¶
- Services: Gitea (web, API, git over HTTPS, Actions) gave no answer or 503 three times for about 10 minutes. Harbor's registry gave 502 in the same windows while
harbor-preupgradedumped (the operator observed 502 from about 18:25 to 18:56 on #1553), but Harbor's front-page probe kept passing. At 13:24:30–13:25:30, all 22 blackbox probes failed for about a minute. - Users: agent work in every organization was held while each merge drained: 15:27:35–16:57, 17:47:26–18:55:40 and 22:31:51–23:37:45, 3 h 44 min in total. Gitea Actions jobs still running at the 30-minute cap of the first two merges ran into the outage: eloro run 12585, eloro run 12630 and Skatzi run 12631. For #1553, the docs release run 12636 failed on Harbor's 502 and was re-run successfully at 18:56.
- Data: none lost. Gitea was stopped, not changed. Each gate verified its backup by restoring it.
- Duration: Gitea down 16:01:30–16:12 (replicas 0 → 1), 18:26–18:36, and 22:56–23:06:30.
/api/healthzfailed from about 30 s after the scale-down until about a minute after the scale-up. The alert fires after 5 minutes, so each firing started 5 minutes into its window.
Timeline¶
All times UTC, 2026-11-18.
| Time | Event | Source |
|---|---|---|
| 13:18:29 | #1362 (Cilium 1.20.4) merged as 524e1c48 |
Git |
| 13:24:13–13:25:24 | Cilium operator, agents and cilium-envoy pods restart on the new version |
kube_pod_start_time |
| 13:24:30–13:25:30 | All 22 blackbox probes fail, Gitea included. Too short for ProbeFailed (5 min) |
probe_success == 0 |
| 15:27:35 | Operator merge run for #1538 (task #3368) holds agent work in 8 organizations | evidence on #1538 |
| 15:57:50 | #1538 (bitnami/kubectl digest, gate container) merged at the 30-minute cap as 514b75e4 |
Git, evidence |
| 16:01:08 | gitea-preupgrade Job starts. 16:01:30: deployment/gitea scaled 1 → 0 |
kube_job_status_start_time, kube_deployment_spec_replicas |
| 16:07:03 | Detected: ProbeFailed for both Gitea probes. Incident #3379 created at 16:08:03 |
alert, task |
| 16:11:55 | Dumps done, Gitea scaled back. Pod gitea-668d986489-87bxt starts; /api/healthz passes from 16:14 |
pod start, probe |
| 16:18:03 | Alert resolved; #3379 closed by Taskbase | task comment |
| 16:22:34 | Gate Complete; backup 20261118T160122Z-28.3.0-to-28.3.0 verified |
Job, evidence |
| 16:57 | Hold released | evidence on #1538 |
| 17:23:38 | #1557 (task #3373) documents tool-image changes in gitea-preupgrade as drain-class |
Git |
| 17:47:26 | Operator merge run for #1553 (task #3382) holds agent work | evidence on #1553 |
| 18:18:00 | #1553 (amazon/aws-cli 2.38.2 → 2.41.0, preflight and publish containers) merged at the cap as ce86bcf2 |
Git, evidence |
| 18:25:30 | Gate starts. 18:26: Gitea scaled 1 → 0 | Job, replicas |
| 18:31:03 | ProbeFailed again; #3379 reopened at 18:32:03 |
task comment |
| 18:35:56 | Gitea back (pod gitea-668d986489-l2lg4); first 200 at 18:37:28 |
pod start, evidence |
| 18:42:03 | Alert resolved; #3379 closed by Taskbase | task comment |
| 18:49:39 | Gate Complete | Job |
| 18:55:40 | Hold released | evidence on #1553 |
| 22:31:51 | Merge run for #1575 holds agent work; fully drained at 22:50 | evidence on #1575 |
| 22:50:22 | #1575 (amazon/aws-cli 2.41.0 → 2.41.1) merged as 003aefab |
Git |
| 22:55:42 | Gate starts, log: Backing up Gitea 28.3.0 (docker.gitea.com/gitea:28.3.0-rootless) before 28.3.0 to hetzner-mgmt/gitea/preupgrade/20261118T225548Z-28.3.0-to-28.3.0. 22:56: Gitea scaled 1 → 0 |
kubectl logs job/gitea-preupgrade -c gate, replicas |
| 23:01:33 | ProbeFailed again; #3379 reopened at 23:02:33 and marked flapping |
task comment |
| 23:06:09 | Gitea back (pod gitea-668d986489-zghfw, the current one); probes pass from 23:08 |
pod start, probe |
| 23:12:33 | Alert resolved; #3379 stays open for a person because it flapped | task comment |
| 23:20:57 | Gate Complete | Job |
| 23:37:45 | Hold released | evidence on #1575 |
Root cause¶
The gitea-preupgrade Job (components/gitea/backup/job.yaml) has kustomize.toolkit.fluxcd.io/force: Enabled, so Flux recreates it whenever its pod template changes. It is meant to run when TARGET_VERSION moves, but its preflight and publish containers (amazon/aws-cli) and its gate container (bitnami/kubectl) are in the same template. A Renovate bump of either image recreates the Job as well. scripts/preupgrade.sh does not compare the running version with TARGET_VERSION. It always scales deployment/gitea to 0, dumps the database and files with the running image, and scales Gitea back before it uploads and restore-checks the backup. So each of these PRs stopped Gitea for about 10 minutes and backed up 28.3.0 "to" 28.3.0.
The pod was replaced because the Deployment went to 0 replicas and back. All four pods of the day belong to ReplicaSet gitea-668d986489, the same one as on 2026-11-15, so the pod template did not change. Helm made no revision, and Gitea restarted 0 times.
This is documented behaviour. Renovate ADR §11, Backup tooling only, says such a PR "runs a full gate, with the writers stopped, against the unchanged target", and the owner accepted that on #1654. Drain before a gate takes a shared service offline makes such PRs drain-class, as of #1557 (task #3373), merged between the first and second window. So the three outages were planned, drained merges, not a fault. They cost three Gitea outages and 3 h 44 min of held agent work in one day, though no version changed. amazon/aws-cli alone released twice that day. harbor-preupgrade ran the same way three times: Backing up Harbor chart 1.19.4 … before 1.19.4.
The one minute at 13:24 is a separate cause: the Cilium upgrade from #1362 restarted the agents and the Envoy that serves the Gateway, so every host failed at once. Harbor's probe failed only in that minute.
What the agent did¶
Only read-only commands. There was no write to the cluster, no silence, no suspend. All commands ran with --context admin@mgmt-cluster (--kube-context for helm) on 2026-11-19 around 06:50 UTC. The steps followed the ProbeFailed runbook, read-only checks first.
kubectl get --raw "$AM/api/v2/alerts"through the Alertmanager Service proxy returned onlyWatchdogandNodeHighMemoryUsage, each labelledcluster=hetzner-mgmt.ProbeFailedwas not firing.$AM/api/v2/silenceshad no active silence, so the alert had really resolved and was not silenced.kubectl get --raw "$PROM/api/v1/query_range?query=probe_success{instance=~"https://gitea.prod.skatzi.com.*"}…"(60 s steps, 12:00–01:00) gave the failure windows 13:25, 16:02–16:13, 18:26–18:37 and 22:57–23:07.flux get kustomizations -Aandflux get helmreleases -Ashowed every object Ready.helm history -n gitea giteashowed the last revision, 12,deployedon 2026-11-15 19:18:47, so Helm made no change on 2026-11-18.kubectl -n gitea get jobs,podsshowedgitea-preupgradeComplete(25 m, age 7h55m, imageamazon/aws-cli:2.41.1) and the Gitea podgitea-668d986489-zghfw, 0 restarts.- Prometheus
kube_deployment_spec_replicas{deployment="gitea"},kube_job_status_start_timeandkube_job_status_completion_time{job_name="gitea-preupgrade"}, andkube_pod_start_timefor the Gitea and Cilium pods gave the scale-downs, gate runs and pod starts in the timeline. kubectl -n gitea logs job/gitea-preupgrade -c gateshowed the28.3.0 … before 28.3.0backup.kubectl -n harbor logs job/harbor-preupgradeshowed the same for Harbor 1.19.4.git log --first-parent mainfor 2026-11-18, plusgit diffof each merge, matched #1538, #1553 and #1575 tocomponents/gitea/backup/job.yaml, and #1362 to Cilium.- Gitea API:
GET /repos/Skatzi/platform/pulls/{1538,1553,1575}and their comments showedmerged_byops-agent, the labeldrain-before-merge, and each run's Upgrade evidence with its hold, drain and resume times. probe_success == 0for all instances at 13:20–13:30 showed all 22 probes failing at 13:24:30–13:25:30.- Read
preupgrade.sh,store.sh latestand the rollback rehearsal. A skip would need a force switch for the rehearsal, which deletes the Job to take a same-version backup. - Created decision #3453 (owner) and task #3454 (
operator, waits for #3453). Wrote this report and added a line to the ProbeFailed runbook in the same pull request.
Resolution and verification¶
At 2026-11-19 06:50 UTC:
- Alertmanager on
hetzner-mgmthas noProbeFailedalert and no silences. https://gitea.prod.skatzi.com/api/healthzreturns 200. Through the Service proxy it reports"status": "pass"withdatabase:pingandcache:pingpassing.flux get kustomizations -A --status-selector ready=falseandflux get helmreleases -A --status-selector ready=falseboth return nothing.
Follow-ups¶
-
3453 (owner's decision): should the backup gates skip the backup when nothing is upgraded (recommended), should Renovate batch the gate's tool images monthly, or should things stay as they are? Answered on 2026-11-22: skip when nothing upgrades, with a force switch for the rehearsal.¶
-
3454 (
operator): carried out the answer forgitea-preupgradeandharbor-preupgrade(the pull request closing issue Skatzi/platform#1596): both gates pass without a backup when the running version equalsTARGET_VERSION, unless the annotationplatform.skatzi.com/preupgrade-forceforces one. Renovate ADR §11, the backup and rollback pages and the drain-class rule were updated with it.¶ - In this pull request: the ProbeFailed runbook now lists a backup gate scaling the backend down as a typical reason.
References¶
- Alert:
ProbeFailed, runbook - Taskbase incident task: #3379
- Pull requests: #1538, #1553, #1575, #1557, #1362
- Docs: Gitea backups: the upgrade gate, Renovate ADR §11: Backup tooling only, Drain before a gate takes a shared service offline
Open questions¶
- Whether a Gitea maintenance or read-only mode could replace the scale-to-0.
preupgrade.shsays only that Gitea before 1.26 had none, and Gitea now runs 28.3.0. This run did not check it.