2026-11-18: harbor-preupgrade health check canceled when the flux2 2.20.0 upgrade replaced kustomize-controller

Kind: reference (incident report)

Severity: warning · Status: resolved · Resolved by: kustomize-controller's next reconcile, checked by the operator agent · Duration: 0:08 from detection to resolution, 19:10:46–19:18:19 UTC · Taskbase task: #3397

Summary

The amazon/aws-cli 2.38.2 → 2.41.0 merge (ce86bcf2, #1553) recreated the harbor-preupgrade gate Job. That is expected for a tooling-only change inside the gate's pod template (Renovate ADR §11, Backup tooling only). While the Kustomization's health check waited on that Job, the flux2 chart 2.20.0 merge (ce536ba3, #1558) replaced kustomize-controller. Stopping the old controller canceled the 45-minute wait, so harbor-preupgrade reported health check failed after 45m20.711805172s: context canceled. The gate itself never failed. The new controller reconciled the same Job, the Job verified its backup and completed, and the Kustomization was Ready at 19:18:19. Nothing was changed on the cluster and nothing was rolled back.

Impact

  • Services: none from this failure. flux-system/harbor-preupgrade was not Ready from 19:10:46 to 19:18:19, and the harbor and harbor-postupgrade Kustomizations waited on it. Harbor's earlier downtime (core, jobservice and registry at 0 from 18:25:41 to 18:45:18 for the dump) was the gate working as designed. It is recorded in the merge run's evidence on #1553 (task #3382) and is not part of this incident.
  • Users: none noticed.
  • Data: none. Backup hetzner-mgmt/harbor/preupgrade/20261118T182540Z-1.19.4-to-1.19.4 was uploaded and verified by restoring it.
  • Duration: 7 min 33 s from detection (19:10:46) to resolution (19:18:19). The fault was only the canceled wait.

Timeline

All times UTC.

Time Event Source
18:18:00 ce86bcf2 merged: amazon/aws-cli 2.41.0, including the preflight and publish containers of harbor-preupgrade commit, #1553
18:25:25 Flux recreated Job harbor/harbor-preupgrade (force: Enabled), pod harbor-preupgrade-qh97m on worker-2. The health check began waiting Job creationTimestamp, startTime
18:25:40 Gate: Backing up Harbor chart 1.19.4 (docker.io/goharbor/harbor-db:v2.15.4) before 1.19.4 gate log
18:25:41–18:45:18 Gate scaled harbor-core, harbor-jobservice and harbor-registry to 0 for the dump, then back gate log
18:45:19–18:56:47 Upload pod harbor-preupgrade-upload ran and succeeded gate log
18:56:49 Restore check started in harbor-scratch gate log
19:10:03 ce536ba3 merged: flux2 chart 2.19.1 → 2.20.0 (Flux 2.10.0) commit, #1558
19:10:34 helm history flux2 revision 10 failed: Upgrade "flux2" failed: context canceled (helm-controller replacing itself) helm history
19:10:40 New kustomize-controller pod kustomize-controller-54fb4bdc88-hkqtr (v1.10.1) started pod startTime
19:10:46 Old pod kustomize-controller-5f79c7c8bb-9k7bz: Stopping container manager, then stopped leading. The same second, detected: HealthCheckFailed, health check failed after 45m20.711805172s: context canceled. Taskbase raised #3397 flux-system events
19:10:58 New kustomize-controller became leader lease kustomize-controller-leader-election
19:11:00–19:12:12 harbor-preupgrade: Dependencies do not meet ready condition, retrying in 30s, while its dependencies reconciled ce536ba3 kustomize-controller log
19:11:30 helm history flux2 revision 11 deployed, flux2-2.20.0 helm history
19:16:06 Gate: Backup hetzner-mgmt/harbor/preupgrade/20261118T182540Z-1.19.4-to-1.19.4 verified. gate log
19:18:09 Gate trap ran resume. Writers were already at their replicas, so nothing changed gate log
19:18:19 Resolved: Job Complete. harbor-preupgrade reported Health check passed in 5m5.042606015s, Applied revision: main@sha1:ce536ba3 Kustomization status
19:19:07 Post-upgrade smoke Job harbor-smoke completed Job status

Root cause

kustomize-controller runs a Kustomization's health check inside the reconcile, bound to the controller's context. harbor-preupgrade health-checks its gate Job, with spec.timeout: 8h5m. When the Deployment is replaced, the old pod's context is canceled, and the wait in progress ends with context canceled rather than a timeout. Flux records that as HealthCheckFailed.

The flux2 chart 2.20.0 changes the kustomize-controller image (now ghcr.io/fluxcd/kustomize-controller:v1.10.1), so the merge of ce536ba3 replaced the pod. That happened 45 minutes into the ce86bcf2 gate. This is the same self-replacement as 2026-10-25, but it hit another controller's in-flight work instead of the flux2 release. The ops runbook covers that case only for HelmRelease flux-system/flux2 (flux2 self-upgrade fails with context canceled).

The gate Job was not affected. ce536ba3 does not touch components/harbor (git diff --stat ce86bcf2 ce536ba3: docs image, flux2 HelmRelease, ci-base Dockerfile, Flux page). So the new controller re-applied an unchanged Job. Its uid 1dc073d4-… and creationTimestamp 18:25:25 are unchanged, it has one pod and no restarts. The new controller waited for the Job to finish.

What the agent did

Read-only only, by the runbook's triage order and its flux2 self-upgrade section. No write command was run on any cluster.

  1. flux --context admin@mgmt-cluster get kustomizations -A --status-selector ready=false and the same for helmreleases: both empty. harbor, harbor-preupgrade and harbor-postupgrade were Ready on main@sha1:ce536ba3.
  2. kubectl --context admin@mgmt-cluster -n flux-system get kustomization harbor-preupgrade -o yaml: Ready and Healthy at 19:18:19, Health check passed in 5m5.042606015s. ce86bcf2 is absent from its history, and the next entry after a8a2576f is ce536ba3.
  3. kubectl --context admin@mgmt-cluster -n harbor get job harbor-preupgrade and its pod: created 18:25:25, Complete at 19:18:19, one pod, 0 restarts. Init gate ran 18:25:38–19:18:09 with exit 0, and publish exited 0.
  4. kubectl --context admin@mgmt-cluster -n harbor logs harbor-preupgrade-qh97m --all-containers --timestamps: writers down 18:25:41–18:45:18, upload succeeded, restore check passed, Backup … verified.
  5. kubectl --context admin@mgmt-cluster -n flux-system get pods and get events: all Flux controllers started 19:10:39–19:10:42. The old kustomize-controller was killed and the HealthCheckFailed event came in the same second, followed by a new leader.
  6. helm --kube-context admin@mgmt-cluster -n flux-system history flux2: revision 10 failed (context canceled), revision 11 deployed on flux2-2.20.0. The self-upgrade had recovered, so the runbook says to change nothing.
  7. curl https://harbor.prod.skatzi.com/api/v2.0/health: every component healthy. helm history harbor: revision 17 deployed, harbor-1.19.4. harbor-scratch held only the completed weekly drill pods.
  8. Roll forward, by the runbook's "it has recovered" case. The next reconcile was already Ready, so no Flux or Helm action was needed. Deleting or recreating the gate Job was rejected: it would take another backup with Harbor's writers stopped. There was nothing to roll back, because the gate changes no version (1.19.4-to-1.19.4).
  9. Task #3399: a runbook follow-up for this case.

Resolution and verification

  • flux get kustomizations -A --status-selector ready=false and flux get helmreleases -A --status-selector ready=false, run at 19:22: both empty.
  • harbor-preupgrade: Applied revision: main@sha1:ce536ba36f1b11ff1276f7aa76ba8ad1f3bb24ae, Healthy.
  • Job harbor/harbor-preupgrade: succeeded: 1, condition Complete. Job harbor/harbor-smoke: completed 19:19:07.
  • Harbor /api/v2.0/health: "status":"healthy". All six Harbor Deployments 1/1.
  • Rollback evidence: none needed. Harbor stays on chart 1.19.4 (Helm revision 17, deployed 2026-11-05), the version the gate backed up and that the backup restored.

Follow-ups

  • 3399: amend the ops runbook so that context canceled on any Kustomization's health check during a flux2 upgrade is recognised, checked read-only, and left alone once the next reconcile is Ready (technical-writer).

References

Open questions

  • Whether the 2026-11-04 harbor Kustomization's context canceled (report, open question) had the same cause, a controller restart. That record does not show it.
  • Whether to keep flux2 merges away from running gate Jobs, for example by also listing gate Jobs in progress before merging a flux2 upgrade. It is cheap to recover from, as here, so this report proposes no rule.